save
•
Press [
]. This advances to the selected CO Line Name/Label database item and shows the current
name/label programmed.
chg
•
Press [
] to input a new name/label.
•
Use the dial pad buttons and the table below to input the name/label for the CO Line. (Important: the
enter
button acts as an
character in the position.
save
•
Press [
] to save the new name/label programming.
next
•
Press [
] to enter another CO Line directory number for programming.
•
When finished programming CO Line Name/Labels, press
Select screen or exit programming.
Programming via PC-DBA
Note: PC-DBA is a DOS-based programming utility.
•
Enter PC-DBA by typing "DX-80" at the DOS prompt in the PC-DBA working directory and then pressing «.
•
Press any key at the program title page (as it requests) to enter the Main Menu.
•
Select PC-DBA from the main menu.
•
Select Programming from the PC-DBA menu. Then press «.
•
Use ¢£¤¥ to highlight "System Resource." Then press «.
•
Use ¢£¤¥ to highlight "CO Line Names." Then press «. The CO Line directory number (740-755) is
listed along the left side of the display. The current name/label programmed is listed adjacent to each
directory number.
•
Use ¢£¤¥ to highlight the CO Line Name to be programmed.
•
Press « to change the data item value.
•
Input the name/label using the PC keyboard.
•
Press « to temporarily store this data.
•
Continue programming other database items as required.
•
When all changes are made press the ° (escape) key to exit this database programming screen. You will
see the prompt: "Exit This Feature"; press "Y" for yes.
•
You will then be prompted to "Save Current Setting?"
•
Press "N" to abort changes and leave all data unchanged.
•
Press "Y" to save changes.
•
If you press "Y" (yes), you will then be prompted "File Exists, Override?"
•
Press "N" to abort changes and leave all data unchanged.
•
Press "Y" (yes) to continue with the save operation.
•
Press ° (escape) again to return to the Database Programming menu.
•
Continue making other programming changes or exit PC-DBA programming.
Note: Changes made via PC-DBA are not updated to the DX-80 system memory until a "SEND" function
has been performed. Please refer to the Programming section of this manual to learn more about this
procedure.
CO Line Programming Copy
This is a programming aid feature. Once one CO Line has been programmed for the configuration settings, those
setting can be copied to other CO Lines using this utility.
P7290 IMM
DX-80 I
M
NSTALLATION AND
AINTENANCE
key. It must be pressed after each character is input to temporarily store that
+
is also used to enter a space.)
3-68
M
03/01
ANUAL
(up or down) to return to the DB Item
+