Router Configuration Parameters
<Time_Setup> Parameters
Parameter
<Auto_Recovery_System_Time>
<Time_Mode>
Provisioning Guide for Cisco SPA100 and SPA200 Series Analog Telephone Adapters
Details
Description: When enabled, allows the ATA to automatically
reconnect to the time server after a system reboot
User Interface: Network Setup > Basic Setup > Time Settings
page, Auto Recovery After System Reboot field
Values:
0: Disabled
1: Enabled
Default: 0
Example: Auto Recovery enabled
<Auto_Recovery_System_Time>1</Auto_Recovery_System_Time>
Description: The method of specifying a time server
User Interface: Network Setup > Basic Setup > Time Settings
page, Time Server field
Values:
0: Manual
1: Auto
Default: 1
Example: Automatic mode
<Time_Mode>1</Time_Mode>
<Time_Setup> Example: Germany Time Zone with Daylight
Savings and Auto-Recovery Enabled
<router-configuration>
...
<Time_Setup>
<Time_Zone>+01 2 2</Time_Zone>
<Auto_Adjust_Clock>1</Auto_Adjust_Clock>
<Time_Server_Mode>auto</Time_Server_Mode>
<Time_Server>0.ciscosb.pool.ntp.org</Time_Server>
<Resync_Timer>3600</Resync_Timer>
<Auto_Recovery_System_Time>1</Auto_Recovery_System_Time>
<Time_Mode>1</Time_Mode>