Cisco SPA1112 Provisioning Manual page 128

Analog telephone adapters
Table of Contents

Advertisement

Voice Parameters
<<Disconnect_Tone_3_>
<FXO_Country_Setting_3_>
<Tip_Ring_Voltage_Adjust_3_>
<Ring_Frequency_Min_3_>
<SPA_To_PSTN_Gain_3_>
<Ring_Frequency_Max_3_>
<PSTN_To_SPA_Gain_3_>
Provisioning Guide for Cisco SPA100 and SPA200 Series Analog Telephone Adapters
Disconnect Tone Script values:
US—480@-30,620@-30;4(.25/.25/1+2)
UK—400@-30,400@-30; 2(3/0/1+2)
France—440@-30,440@-30; 2(0.5/0.5/1+2)
Germany—440@-30,440@-30; 2(0.5/0.5/1+2)
Netherlands—425@-30,425@-30; 2(0.5/0.5/1+2)
Sweden—425@-10; 10(0.25/0.25/1)
Norway—425@-10; 10(0.5/0.5/1)
Italy—425@-30,425@-30; 2(0.2/0.2/1+2)
Spain—425@-10; 10(0.2/0.2/1,0.2/0.2/1,0.2/0.6/1)
Portugal—425@-10; 10(0.5/0.5/1)
Poland—425@-10; 10(0.5/0.5/1)
Denmark—425@-10; 10(0.25/0.25/1)
New Zealand—400@-15; 10(0.25/0.25/1)
Australia—425@-13; 10(0.375/0.375/1)
The country of deployment. This setting applies the relevant
regional settings for PSTN calls.
Default setting: USA
Voltage adjustment. The choices are 3. 1 V, 3.2V, 3.35V, and
3.5V.
Default setting: 3.5V.
The lower limit of the ring frequency used to detect the ring
signal.
Default setting: 10
dB of digital gain (or attenuation if negative) to be applied to
the signal sent from the ATA to the PSTN side. The range is -15
to 12.
Default setting: 0
The higher limit of the ring frequency used to detect the ring
signal.
Default setting: 100
dB of digital gain (or attenuation if negative) to be applied to
the signal sent from the PSTN side to the ATA. The range is -15
to 12.
Default setting: 0