Racal Instruments 3155 User Manual page 199

100ms/s arbitrary waveform generator
Table of Contents

Advertisement

User Manual 3155
Mixed Sequence Advance
Advance Source
Sequencer steps
Segment loops
OUTPUTS
Waveform Output
Connector
Stand-by (Output Disconnected)
Impedance
Protection
Amplitude
Range
Resolution
Accuracy (1 KHz)
800 mV to 8 Vp-p
80 mV to 799.9 mVp-p
Offset
Offset
Range
Resolution
Accuracy
±4 V window
±400 mV window
Filters
Square Wave, Pulse
Rise/Fall time
Aberration
SYNC/Marker Output
Description
Connector
Impedance
Each step of a sequence can be programmed to advance
either a) automatically (Automatic Sequence Advance), or b)
with a trigger (Stepped Sequence Advance).
External, Internal, or soft trigger
From 1 to 4096
From 1 to 128 K
Front panel BNC
Output Off or Normal
50Ω, ±1%
Protected against temporary short to case ground
80 mV to 8 Vp-p, into 50Ω; Double into open circuit
3.5 digits
±(1% + 10 mV)
±(1% + 1 mV)
Offset is attenuated with amplitude
0 to ±3.6 V, amplitude dependent
22 mV
±(1% of reading + 1% of amplitude + 2 mV)
±(1% of reading + 1% of amplitude + 200 µV)
25MHz or 50 MHz low pass elliptic filter, 7-pole elliptic
(Selectable)
<10 ns, 10% to 90% of amplitude
<5%
Provides dual functionality. All functions and modes, this
output generates sync pulse, which is synchronous with the
output waveform. In FM and sweep modes only, this output
generates a marker having properties similar to the sync
pulse output.
Front panel BNC
50Ω, ±1%
Specifications A-5