Figure 3-99: Reset Confirmation Message Box - AudioCodes MediaPack MP-124 User Manual

Mediapack mp-11 series cpe & access analog gateways
Hide thumbs Also See for MediaPack MP-124:
Table of Contents

Advertisement

Under the 'Reset Configuration' group, from the 'Graceful Option' drop-down list, select
3.
one of the following options:
'Yes': Reset starts only after the user-defined time in the 'Shutdown Timeout' field
(refer to Step 4) expires or after no more active traffic exists (the earliest thereof).
In addition, no new traffic is accepted.
'No': Reset starts regardless of traffic, and any existing traffic is terminated at
once.
In the 'Shutdown Timeout' field (relevant only if the 'Graceful Option' in the previous
4.
step is set to 'Yes'), enter the time after which the device resets. Note that if no traffic
exists and the time has not yet expired, the device resets.
Click the Reset button; a confirmation message box appears, requesting you to
5.
confirm.
Click OK to confirm device reset; if the parameter 'Graceful Option' is set to 'Yes' (in
6.
Step 3), the reset is delayed and a screen displaying the number of remaining calls
and time is displayed. When the device begins to reset, a message appears notifying
you of this.
Notes:
3.5.1.3.2 Locking and Unlocking the Device
The Lock and Unlock options allow you to lock the device so that it doesn't accept any new
incoming calls. This is useful when, for example, you are uploading new software files to
the device and you don't want any traffic to interfere with the process.
To lock the device, take these 5 steps:
Open the 'Maintenance Actions' page (refer to ''Maintenance Actions'' on page 207).
1.
Under the 'LOCK / UNLOCK' group, from the 'Graceful Option' drop-down list, select
2.
one of the following options:
'Yes': The device is 'locked' only after the user-defined time in the 'Lock Timeout'
field (refer to Step 3) expires or no more active traffic exists (the earliest thereof).
In addition, no new traffic is accepted.
SIP User's Manual

Figure 3-99: Reset Confirmation Message Box

Throughout the Web interface, parameters preceded by the lightning
symbol are not applied on-the-fly to the device and require that you reset
the device for them to take effect.
If you modify parameters that only take effect after a device reset, after
you click the Submit button, the toolbar displays the word 'Reset' (refer to
''Toolbar'' on page 23) to remind you to later reset the device.