8.4.4.5 Removing the Fixing Unit

iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the two screws [1], and then detach the inner cover [2] at the
upper front.
2) Remove the screw [1], and then detach the heater harness cover [2].
Disconnect the connector [3].
[2]
[3]
[1]
3) Disconnect the two connectors [1], and then release the fixing unit harness
from the wire saddle [2].
8-18
F-8-76
[1]
[2]
[1]
F-8-77
F-8-78
4) Raise the delivery upper guide [1]. Remove the three screws [2], and then
remove the fixing unit [3].
0010-9955
[2]

8.4.4.6 Removing the Fixing Delivery Sensor

iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove the resin ring [1], and then remove the fixing pressure release
lever [2].
When installing the fixing pressure release lever, check that the rib [1] of the
lever is inside the pressure block [2].
[1]
F-8-79
[1]
[3]
[2]
F-8-80
[2]
[1]
F-8-81
[2]
0010-9960