3) Open a core [1].
4) Remove the two screws [1], and then detach the flexible cable guide [2].
5) Remove the 10 screws [1], and then detach the IP cover [2].
[1]
[2]

9.4.11.8 Removing the Image Processor PCB Mount

iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
[1]
F-9-92
[1]
F-9-93
[2]
[1]
F-9-94
[1]
[1]
F-9-95
1) Disconnect the two reader flexible cables [1]. Release the harness [2] from
the wire saddles [3]. Remove the two screws [4], and then detach the
flexible cable cover [5].
[4]
2) Turn over the reader flexible cable cover [1], and then secure to the back
of the reader temporarily using a screw [2].
[2]
3) Disconnect all connectors and remove the five screws [2], then remove the
image processor PCB with the PCB mount.
0011-0626
[3]
[2]
[1]
F-9-96
[1]
F-9-97