14.4.5 <No.008 V.34 modulation speed upper limit>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set an upper limit to the modulation speed (baud rate) for the V.34 primary channel.
14.4.6 <No.009 V.34 data speed upper limit>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set an upper limit to the data transmission speed for the V.34 primary channel between 2.4K and 33.6K bps in increments of 2400 bps. (0: 2.4K to 13:
33.6K bps).
14.4.7 <No.010 Frequency of the pseudo CI signal>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
You may select a frequency for the pseudo CI signal.
Some types of external telephones do not ring when the fax/tel switch-over function is ON. To sound the ring, change the pseudo CI signal.

14.5 Setting of Numeric Parameter (NUMERIC Param.)

14.5.1 Numerical Parameter Composition

iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
14.5.2 <002: RTN transmission condition (1)><003: RTN transmission condition (2)><004: RTN transmission condition (3)>
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set RTN signal transmission conditions. Raise these parameters for more lenient conditions if errors occur frequently at time of reception because of trans-
mission of the RTN signal.
Memo:
Any of the following error codes may be indicated at time of reception because of RTN signal transmission
##0104, ##0107, ##0114, ##0201
RTN signal transmission condition (1) affects the ratio of error lines to the total number of lines per single page of received images.
RTN signal transmission condition (2) affects the standard value (*2) of burst errors (*1).
RTN signal condition (3) affects the number of errors not reaching the standard value of burst errors.
*1: transmission error occurring cover several lines.
*2: for instance, if '15' is set, a single burst error will represent an error occurring continuously cover 15 lines.
If any of these lines is detected while an image signal is being received, the RTN signal will be transmitted after receiving the protocol signal of the transmitting
party. Higher parameters restrict the transmission of the RTN signal.
No.
Item
002
RTN transmission condition(1)
003
RTN transmission condition (2)
004
RTN transmission condition (3)
005
NCC pause time length (pre-ID code)
006
NCC pause time length (post-ID code)
010
line condition identification time length
011
T.30T1 timer (for reception)
013
T.30 EOL timer
015
hooking detection time length
016
time length to first response at time of fax/tel switchover
017
pseudo RBT signal pattern ON time length
018
pseudo RBT signal pattern OFF time length
(short)
019
pseudo RBT signal pattern OFF time length
(long)
020
pseudo CI signal pattern ON time length
021
pseudo CI signal pattern OFF time length
(short)
022
pseudo CI signal pattern OFF time length (long)
023
CNG detection level at time of fax/tel switchover
024
pseudo RBT transmission level at time of fax/tel switchover 10 to 20
025
Answering machine connection function signal detection
time
027
preamble detection time length for V21 low-speed flag
056
display the type of soft counter 1
057
Display the type of soft counter 2
058
Display the type of soft counter 3
059
Display the type of soft counter 4
060
Display the type of soft counter 5
061
Display the type of soft counter 6
T-14-16
Range of settings
1% to 99%
2 to 99 item
1 to 99 lines
1 to 60 sec
1 to 60 sec
0 to 9999 (10 msec)
0 to 9999 (10 msec)
500 to 3000 (10 msec)
0 to 999
0 to 9
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
0 to 7
0 to 20 (120/230V)
0 to 999
20 (x 10ms)
101 (Fixed)
0 to 999
0 to 999
0 to 999
0 to 999
0 to 999
Chapter 14
0011-1773
0011-1774
0011-1775