Heat Control; Cool Control; Compressor Delay - Proliphix NT10e Configuration Manual

Hide thumbs Also See for NT10e:
Table of Contents

Advertisement

Rev 2.0
If HVAC Type is Fuel Burner:

Heat Control

Specifies the HVAC control of this thermostat. This parameter describes the thermostat
capability to control a single stage heating system. The thermostat can also be disabled
from controlling a heating system and instead operate as a cool-only thermostat. (See Fuel
Burner:Cool Control).
Status and Control:
Disable - Specifies that there is no heating system present. (A/C only thermostat.)
Enable - Enables the heating system as a standard single stage system.

Cool Control

Specifies the HVAC control of this thermostat. This parameter describes the thermostat
capability to control a single stage cooling system. The thermostat can also be disabled
from controlling a coling system and instead operate as a heat-only thermostat. (See Fuel
Burner:Heat Control).
Status and Control:
Disable - Specifies that there is no cooling system present. (Heat only thermostat.)
Enable - Enables the cooling system as a standard single stage system.

Compressor Delay

Specifies the minimum time (in minutes) between successive A/C cycles. This parameter
ensures a safe A/C compressor delay or off time guaranteed between cycles.
Status and Control:
0 – This enables the cooling system to cycle immediately upon completion of the previous
cycle. This is included as a diagnostic feature and should not be left in this state or
compressor short cycling and subsequent damage may occur to the compressor.
3 thru 10 – Time in minutes required between the completion of a cooling cycle and the next
subsequent cooling cycle. Default delay is 3 minutes.
Page 45 of 54

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nt20e

Table of Contents