Sw Ver / Hw Rev; Display Contrast; Alarms; Low Temp(Erature) Limit - Proliphix NT10e Configuration Manual

Hide thumbs Also See for NT10e:
Table of Contents

Advertisement

Rev 2.0

SW Ver / HW Rev

Software Version / Hardware Revision
Status:
Software version number followed by Hardware revision number.

Display Contrast

LCD display contrast control. Values range from 25 (lowest contrast between the graphics
characters and the background) to 40 (highest character contrast to the background).
Status and Control:
25 to 40, the default value is 35

Alarms

Low Temp(erature) Limit

Low temperature threshold detection. The value set by this parameter will be monitored by
the thermostat and compared against the current Zone Temperature. If the current Zone
Temperature falls below this value, an alarm condition is set and the status is displayed on
the Status & Control Page. In addition, this alarm will be sent to the Proliphix web site to
trigger an email notification if this function is enabled. (See Remote Access Page). This is a
major (red) alarm condition.
If a Low Temp Limit alarm is pending, specific action must be taken to clear this condition.
In Figure 16b, a Low Temp Limit alarm is set and is noted by the presence of the Heating
Alarm Dismiss field. Note that the "Condition repaired" box must be checked and the
condition must be repaired (i.e. the zone temperature must be above the set Low Temp
Limit or the Low Temp Limit is set to "Disable" for the alarm condition to be cleared upon a
Submit.
Status and Control:
Disabled (Default) – no lower temperature limit is set.
o
45

High Temp(erature) Limit

High temperature threshold detection. The value set by this parameter will be monitored by
the thermostat and compared against the current Zone Temperature. If the current Zone
Temperature rises above this value, an alarm condition is set and the status is displayed on
the Status & Control Page. In addition, this alarm will be sent to the Proliphix web site to
trigger an email notification if this function is enabled. (See Remote Access Page). This is a
major (red) alarm condition.
If a High Temp Limit alarm is pending, specific action must be taken to clear this condition.
In Figure 16b, a High Temp Limit alarm is set and is noted by the presence of the High
Temp Dismiss field. Note that the "Condition repaired" box must be checked and the
zone temperature must be below the set High Temp Limit or the High Temp Limit is set to
"Disable" for the alarm condition to be cleared upon a Submit.
Status and Control:
Disable (Default) – no high temperature limit is set
o
45

Filter (change) Reminder

This convenience feature will remind the user that the HVAC system requires maintenance.
Specifically this feature will allow the user to set time intervals between HVAC filter changes
or cleanings. If enabled, an alarm condition will be set after the pre-set interval has expired,
o
F to 94
F
o
F to 94
F
Page 29 of 54