3-19.
INFORMATION
MODE
July 2003
This mode gathers and stores historic information on the fryer
and operator's performance. Press (PROG►) and (◄INFO) at
the same
time and "*INFO MODE*" shows on display. Press (PROG►)
or (◄INFO) to access the steps and press ▼ to view the statistics
within each step. Information Mode is intended for technical use,
but the operator can view the following information:
1. E-LOG - last 10 errors and time they occurred
2. LAST LOAD - information about the most recent Cook
Cycle, or the cycle presently in progress
3. DAILY STATS - information for the last 7 days
4. REVIEW USAGE- information accumulated since the last
time this data was manually reset
5. INP A VHDSF PM.PM - provides test of fryer inputs
6. OUTP - shows the state of heater and pressure
7. OIL TMP - temperature of shortening
8. CPU TMP - temperature of PC board
9. ANALOG - status of controller's a-to-d converter
Press and hold (PROG►) to exit Information Mode at
any time, or after 2 minutes, controls automatically exit
back to normal operation.
1. E-LOG (error code log)
Press ▼ and "1A" (date & time) "*NOW*" show in display.
This is the present date and time.
Press ▼ and if a error was recorded, "1B" (date, time, and error
code information) shows in display. This is the latest error code
that the controls recorded.
Press ▼ and the next latest error code information can be seen.
Up to 10 error codes (1B to 1K) can be stored in the E-LOG
Section.
Press (PROG►) to continue to LAST LOAD.