EPSON Stylus Pro 7500
4.2.3.14 Removing the P_FRONt Sensor Assembly
1.
Remove the R Side Cover as described in "R Side Cover Removal" on page 103.
2.
Remove the L Side Cover as described in "L Side Cover Removal" on page 104.
3.
Remove the I/C Holder Cover as described in "I/C Holder Cover Removal" on
page 105.
4.
Remove the H Top Cover as described in "H Top Cover Removal" on page 105.
5.
Remove the Rear Cover as described in "Rear Cover Removal" on page 106.
6.
Remove the paper Guide L2 as described in "Paper Guide L2 Removal" on page 107.
7.
Disconnect the harness for the P_FRONT Sensor Assembly from the connector on the
main board and drop the harness in the hole on the right.
8.
Push the paper hold lever down to the front.
9.
Remove the three (CUPS M4x6) screws securing the Paper Guide L, and remove the
Paper Guide L by slowly taking it out toward upper front.
NOTE: To remove the left screw, insert a screw driver from the space of the I/H
Assembly, the third one from the right.
10. Remove the two (CP(W) M2x8) screws securing the P_FRONT Sensor Assembly and
remove the P_FRONT Sensor Assembly.
NOTE: P_FRONT Sensor Assembly position is adjusted at factory. Therefore, be
sure to mark its current position before removing the screws.
If you replace the P_FRONT Sensor Assembly, perform the necessary
adjustment listed in Table 5-2 in Chapter 5 on Page172
Disassembly & Assembly
Figure 4-89. Removing the Paper Guide L
screws(M2x8)
Figure 4-90. Removing the P_FRONT Sensor Assembly
Disassembly Flow
(+)
driver
screws(M4x6)
P_FRONT sensor
assembly
Revision A
paper guide L
142