CDM-800 Gateway Router
Ethernet Management
Modem
Unit Name – The assigned product label is identified here.
System Contact / System Location – E-mail and telephone contact information for Comtech EF
Data Customer Support are provided here.
Click [Submit] once the desired changes have been made to these items.
Set Time (hh:mm:ss) – Enter a time using HH:MM:SS format (where HH = hour [00 to 23],
MM = minutes [00 to 59], and SS = seconds [00 to 59]).
Set Date (dd/mm/yy) – Enter a date using the European time format DD/MM/YY (where
DD = day [01 to 31], MM = month [01 to 12], and YY = year [00 to 99]).
Click [Submit] once the desired changes have been made for these functions.
Circuit ID – Enter a Circuit ID string consisting of 4 to 24 characters.
Click [Submit] once the desired string has been entered for this function.
(FUTURE)
Warm Up Countdown – This selection is not operable in this initial product release.
(FUTURE)
Warm Up Delay – This selection is not operable in this initial product release.
(FUTURE)
G.703 Clock Extended Mode – This selection is not operable in this initial product
release.
10 MHz Internal Adjustment – Enter a value from -999 to (+)999, then click [Submit] as
needed to save this setting.
External Reference Frequency – Use the drop-down menu to set the External Reference
Frequency function/value as Internal, External 1 MHz, External 2 MHz, External 5 MHz,
External 10 MHz, or Internal 10 MHz plus External. Click [Submit] as needed to save this
setting.
Test Mode – Use the drop-down menu to select test mode as follows:
•
Normal Mode – This mode clears any test modes or loopbacks, and places the unit back
into an operational state.
•
Tx CW – This test mode forces the modulator to transmit a pure carrier (unmodulated).
•
Tx Alt 1/0 – This mode is used to check the carrier suppression of the modulator. Selecting
this test mode forces the modulator to transmit a carrier modulated with an alternating
1,0,1,0 pattern, at the currently selected symbol rate. This causes two discrete spectral lines
to appear, spaced at ± half the symbol rate, about the carrier frequency.
Click [Submit] once the desired Test Mode has been selected.
Save/Load Configuration
This section allows the user to save, then load (recall) up to 10 configuration sets.
To save a configuration set: After all configuration parameters have been adjusted to suit, use the
top (Save) Select Location dropdown to select 0 through 9, then click [Save Configuration] as
needed to store the specified configuration settings.
To load (recall) a configuration set: Use the bottom (Load) Select Location dropdown to select 0
through 9, then click [Load Configuration] as needed to recall the selected configuration
settings.
5–27
Revision 0
MN-CDM800