Ignition And Starter Lock; Chronometer; Main Fuse - Husqvarna Rider ProFlex 21 II Workshop Manual

Hide thumbs Also See for Rider ProFlex 21 II:
Table of Contents

Advertisement

For Husqvarna Parts Call 606-678-9623 or 606-561-4983

Ignition and Starter Lock

1.
Remove the right-hand side cover from
the lever housing.
2.
Release the contact box from the ignition
lock by pulling it straight down.
3.
Remove the ignition key and the rubber
seal.
4.
Remove the nut and the ignition lock.
5.
Attach the parts in the reverse order.
Make sure the contact box ends up in
the proper position (click-lock).

Chronometer

1.
Remove the right-hand side cover from
the lever housing.
2.
Release the cables from the
chronometer.
3.
Drill out the rivets attaching the
chronometer from above.
4.
Attach the parts in the reverse order. The
chronometer may be attached with nuts,
bolts, and spring washers if suitable
rivets are unavailable.

Main Fuse

The fuse is placed in a detachable holder
under the battery case's cover, in front of the
battery.
Type: Flat pin, 15 A.
Do not use any other type of fuse when
replacing.
A blown fuse needs to be replaced. Pull the
fuse from the holder when replacing.
The fuse is there to protect the electrical
system. If it blows again shortly after
replacement, it is due to a short circuit, which
must be fixed before the machine can be put
into operation again.
74