Hour meter

1. Remove the right-hand side cover from the
lever housing.
2. Release the cables from the hour meter.
3. Drill out the rivets attaching the hour meter from
above.
4. Assemble the parts in the reverse order. The
hour meter may be attached with screws, nuts
and spring washers if suitable rivets are
unavailable.

Main fuse

The fuse is placed in a detachable holder under the
battery case's cover, in front of the battery.
Type: Flat pin, 15 A.
Do not use any other type of fuse when replacing.
A blown fuse is indicated by a burnt connector.
Pull the fuse from the holder when replacing.
The fuse is there to protect the electrical system. If
it blows again shortly after replacement, it is due to
a short circuit, which must be fixed before the
machine can be put into operation again.
www.mymowerparts.com

Ignition and Starter Lock

Rider 15V2 and Pro 15
1. Loosen the right-hand wing cover.
2. Remove the inner protecting plate on the gear
lever carrier.
3. Release the contact box from the ignition switch
by pulling it straight down.
4. Remove the ignition key and the rubber seal.
5. Remove the nut and the ignition switch.
Rider Pro 18
1. Remove the right-hand side cover from the
lever housing.
2. Release the contact box from the ignition switch
by pulling it straight down.
3. Remove the ignition key and the rubber seal.
4. Remove the nut and the ignition switch.
Assemble the parts in the reverse order. Make
sure the connector ends up in the proper
position (click-lock).
Electrical system
69