Superswitch volume iv (generic 217)
Hide thumbs Also See for sx-100:
Table of Contents

Advertisement

DC/DC
CONVERTER
POWER IS
NIGHT
- 4 a v
CONTROLLED BY
BELL
NIGHT
SVSTEM POWER
TB2.4
6-4 SX-200
Figure
Back Door
6.08
When troubleshooting the systems for power failures, the Pow-
er Supply Block Diagram (Figure 6-7), and Charts 6-l through
6-10 should be consulted. The charts outlined cover the trouble and its
effect on the system. In most cases the repair person will be directed
to a specific MAP for remedial action. Under the heading "Check", a yes
answer to the question asked is an indication to go on to the next
question in the "Check" column. If a no answer is encountered, the
repair person should.go to the "Action" column and follow the instruc-
tions listed there. There is also a column indicating (by an X) to which
system the action applies. Above all, it must be remembered that fuse
replacement is not a remedy. The probable cause of a power failure
should be determined before the system is powered-up. Utilizing the
information provided in this Section and the MAPS referred to in Charts
SECTION MITL91 OS/91
CONVERTER INPUT LED
,
BELL
F U S E
TB2.1
Tf32.3
I
OPTIONAL
R E S E R V E
BATTERY
Electrical
Schematic
AC
P O W E R
L E D
EA
A
B R
K E R
Page 77
x1473