SECTION MITL9105/911 O-096-350-NA
EXTENDED PROGRAMMING ERROR CODES - SUPERSET PROGRAMMING
irror
Involved
E43
E44
E45
E50
E51
E52
Special set error numbers are arranged in groups, with each numerical group having a general
significance. The groups are:
EO - Eg No special significance.
l
El0 - El9 The required parameters were not entered.
l
. E20 - E29 There are incompatibilities with the database values and the parameter
values being entered to define or change a key.
E30 - E39 There are prerequisites to the operation being attempted which have not
l
been satisfied.
.
E40 - E49 The desired operation cannot be performed due to system activity
involving the set or key selected.
. E50 - E59 The desired operation cannot be performed due to internal system
limitations.
Note:
An E5 error will be given when entering (or moving) a SUPERSET equipment number to a
slot that would indicate more than eight slots programmed.
Page 50
TABLE 4-12 (CONT'D)
message waiting, and deletion is not allowed.
An attempt was made to delete a prime, but the set has a
An attempt was made to delete a Non-Prime/key, but the key
was not idle, and deletion is not allowed. Also given when
one of the Non-Prime keys is not idle when a deletion is
attempted.
An attempt was made to add a Prime key, but 64 sets have
already been defined.
An attempt was made to add a Non-Prime key which
requires an internal system resource, of which all have been
used. If any multiple call key, or an entire primeless key line
list is deleted, one resource will be freed.
An attempt was made to add a Non-Prime key which
requires an internal system resource. This time, if either a
complete DTS or private line list is deleted, one internal
resource will be freed.