Code
a)
SRW-1 error
SRPC-1 error
0077
—
0078
—
0079
—
007A
—
007C
—
007D
—
007F
—
a) When an SRW-1 error is detected, the error code is displayed following
the indication "VTR:".
b) When an SRPC-1 error is detected, the error code is displayed following
the indication "VA:".
About Warning Messages
If one of the conditions described in the table of warning
messages (see page 107) is detected, a warning message
code appears in the operation status and warnings section
of the control panel display (see page 15). This section is
visible when the display is showing the HOME screen.
Note
Warning messages do not appear unless the display is
showing the HOME screen. To display the HOME screen,
press the HOME button on the control panel.
To check the content of warning messages
Press the SELECT/ENTER dial on the control panel. A
popup window appears to display messages for the current
warnings.
Only one message is displayed at one time, even if
multiple warnings occur. But the number of current
warnings appears at the bottom of the popup window.
106
Error Messages and Warning Messages
Message
b)
F-TOP SENSOR ERR
SLACK-32
SLACK-42
SLACK-33
SLACK-34
SLACK-44
HUMID ERROR
Description
FULL TOP sensor error was detected.
(Exchange the sensor.)
S-reel FG error was detected.
T-reel FG error was detected.
S-reel direction error was detected.
S-reel speed error was detected.
T-reel speed error was detected.
Condensation detector detected condensation.
Example:
Popup window displaying warning message
"VTR: 0010 TELEFILE FULL"
dB
ANA
ANA
SDI
SDI
SDI
0
-10
-20
W AR NI NG
-30
-60
EMP
EMP
EMP
EMP
EMP
PB
L R
L R
L R
L R
L R
1
2
3
4
5
VTR:0010
VTR:0010
TELEFILE FULL
TELEFILE FULL
OOOO
PLAY LOCK
TCR
LTC INTRP
DF
Telefile Memory is Full
00
00
H
M
O Error(s)/
12.2V
REMAIN
CH.COND
18min
There is no current error (see page 104).
There are three current warnings.
To view the other messages, rotate the SELECT/ENTER dial
on the control panel.
When a warning message appears
Take any action that may be needed to eliminate the cause
of the warning.
SDI
SDI
SDI
SDI
SDI
A/E
A/E
EMP
EMP
EMP
EMP
EMP
EMP
EMP
L R
L R
L R
L R
L R
L R
L R
6
7
8
9
10
11
12
VTR OOOOO
EXT-LK
KEYINHI
RECINHI
00
00
S
F
3 Warning(s)
IN: --:--:--:--
1080
LOCAL
S59P
PB
(29PsF)
4:2:2