ISR Messages

When the BKPF-500 ISR Interface Board is installed,
the following messages are sent to the ISR system
under any of the following conditions.
Message
• POWER OFF/OVER TEMP/FAN STOP
Conditions
One of the following conditions occurs with either of
the power units.
1. The temperature inside the unit has risen over a
specified level.
2. The ventilation fans have stopped rotating.
3. Trouble occurs with the output voltage at either of
the two power supply units.
4. A voltage load exceeds the specified level.
For the ISR messages for the installed optional boards,
refer to the operation manuals supplied with the board
and the BKPF-500.
8 (E)

Specifications

Power requirements
100 to 240 V AC, 50/60 Hz
Current drain
100 V AC: max. 1.8 A
240 V AC: max. 0.9 A
Peak inrush current
(1) Power ON, current probe method:
30 A (100 V), 40 A (240 V)
(2) Hot switching inrush current, measured in
accordance with European
standard EN55103-1:
20 A (230 V)
Power supply capacity +5 V DC: max.8 A
–5 V DC: max.8 A
Operating temperature 5°C to 40°C (41°F to 104°F)
Storage temperature
–20°C to +60°C (–4°F to
+140°F)
Operating humidity
10% to 90%
424 × 132 × 428 mm (w/h/d)
Dimensions
(16
Mass
Approx. 8 kg (17 lb 10 oz)
(not including the optional
boards)
Status output
STATUS OUT: D-sub 25-pin
Supplied accessories
Operation Manual (1)
Installation Manual (1)
Design and specifications are subject to change
without notice.