1.
Ensure the access panel latch is in the open position (pointing up) before replacing the access
cover.
See
Figure 39 (page
2.
Place the access panel on the blade with the panel hanging over the back of the enclosure
about 1.25 cm (0.5 in).(1).
See
Figure
3.
Slide the access panel toward the front of the server until the access panel clicks into place
(2).
4.
Close the access panel latch (3).
5.
lock the cam on the access panel latch (if necessary) by turning the lock on the latch clockwise
with a 2.5 mm allen wrench.
6.
Place the server blade back into the enclosure and power it on.
See
"Preparing the Server Blade for Servicing" (page
Figure 39 Replacing the Server Blade Access Panel

Removing and Replacing Internal Components

These procedures describe how to remove and replace the internal components in the server blade.
The server blade contains the following field replaceable units (FRUs).
NOTE:
All FRUs are also customer replaceable units (CRUs) except the TPM. The TPM must be
serviced by authorized HP personnel only.
DIMMs
Processors
SAS backplane
Front display board
Mezzanine cards
113).
39.
110).
Removing and Replacing Internal Components
1 13