provides the needed multidrop operation by means of multicast
addressing, where multiple remote devices receive and process the same
poll message.
On the other hand, TCP services are best suited for applications that do
not have a recovery mechanism and must have the guaranteed delivery
that TCP provides despite its extra overhead. The IP-to-Serial example
shows how to do this.
See "IP-to-Local Serial Application Example" on
Page
121.
To configure either of these services, use the Serial Configuration Menu
(Figure 3-22 on Page
57).
To configure IP-to-remote serial services, use the Remote Serial
Gateway Menu
(Figure 3-28 on Page
64).

Configuration

There are several configuration parameters for the remote serial gateway
found under the Serial Configuration Menu. Note that some of the
parameters are not applicable to IP-to-serial mode. After making
changes to the configuration, you must use the
option to
Commit Changes
force the transceiver to implement the requested changes.
If you are connecting EIA-232 serial devices to the transceiver, review
these parameters carefully.

Serial Configuration Wizard

The Serial Configuration Wizard, available through the Local Serial
Configuration Menu, is recommended for configuration of serial ports.
The Wizard uses a step-by-step process that eliminates conflicting
settings and streamlines complex configurations.
56
MDS entraNET Technical Manual
05-4055A01, Rev. E