Step-By-Step Instructions For Configuring A Point-To-Point Serial Connection - GE MDS entraNET 900 Technical Manual

900 mhz and 2400 mhz extended range ip networking transceivers
Table of Contents

Advertisement

124
Figure 5-4. Point-to-Point Serial-to-Serial Application Diagram
Use the Serial Configuration Wizard (Local Serial Configuration menu)
to make the settings listed in the table below. Following the table are
step-by-step screen images of the Wizard.
Table 5-4. Point-to-Point Serial-to-Serial Configuration
MDS entraNET
radio Location
AP (COM2)
Remote radio (COM2)
5.4.1 Step-by-step Instructions for Configuring a
Point-to-Point Serial Connection
1. Connect a powered AP radio to a PC.
2. At the PC, open a connection with the Access Point radio using a
terminal, Telnet, or Web browser session.
3. Press
to display the Main Menu.
G
MDS entraNET Technical Manual
Invisible place holder
Menu Item
Setting
Port Status
Enabled
Mode
Serial-to-Serial
Remote UnitID
1155999 (example)
Rem. COM Port
COM2
Baud Rate
19200
Byte Format
8N1
Buffer Size
256 Bytes
Inter-Packet Delay
4
Mode
Data
Baud
19200
Format
8N1
Buffer
256
DelayChars
4
05-4055A01, Rev. E