HELP
LOG
112
—Displays all settable optional arguments and their current values.
CMD
You can copy this list to a text file as a record of your configuration.
—Number of hand-offs that occurred.
COUNT=<integer>
—Sets or displays the hand-off configuration, or disables
MODE=<mode>
hand-offs.
: Hand-off is deactivated.
OFF
: The Remote hands off when
ACK
programmed threshold
: The remote hands off when
RSSI
programmed threshold
: The remote hands off when either
ACKRSSI
falls below its programmed threshold.
RSSIAVG=
RSSIAVG=<RSSI -dBm>
determined by sampling, as defined by
RSSIAVGINT=<integer>
One sample every 61 hops
1:
Two samples every 122 hops
2:
Four samples every 244 hops
4:
Eight samples every 488 hops
8:
16 samples every 976 hops
16:
32 samples every 1952 hops
32:
64 samples every 3904 hops
64:
128 samples every 7808 hops
128:
256 samples every 15616 hops
256:
RSSIAVGTHRESH=<RSSI -dBm>
averaging (–120 dBm to –50 dBm).
Lists commands supported for the current user log-in level.
Sets or displays the event log information, and displays the number of
entries in the event log. Optional arguments are used to clear or display
the log.
Optional arguments:
—Clear the event log
CLEAR
—Show the event log
SHOW
—Number of event log entries in log. Read only.
TOTAL=
—Displays all settable optional arguments and their current values.
CMD
You can copy this list to a text file as a record of your configuration.
MDS entraNET Technical Manual
ACKAVG=
ACKAVGTHRESH=
RSSIAVG=
RSSIAVGTHRESH=
—Current RSSI average dBm. This average is
RSSIAVGINT=
—RSSI sampling frequency, defined as:
—The hand-off threshold for RSSI
is below the
.
is below the
.
or
ACKAVG=
.
05-4055A01, Rev. E