Peak Hold

All Meters (LED Meters on the Surface and the Screen Meters) offer a PEAK HOLD function with auto
release.
The Peak Hold time (same for all Meters) is currently fixed, but in a future software release will be adjust-
able via the 'Settings' page.

Ballistics

The metering ballistics for all level meters is according to the PPM (peak program meter) DIN standard,
with the difference that the attack time is audio sample based (20.8 uS @ 48 kHz) and has no integration
time.
The GRMs have no ballistics, because they show the actual dynamics control value (with time constants
according to those set by the user in the Dynamics VST page).