6. Optical Specifications
6.1. Imager Scanning
Parameter
Scanning method
Effective pixels
Frame rate
Aiming LED wavelength
(2 green LEDs)
Lighting LED wavelength
(4 red LEDs)
View angle
Focal length
Notes:
Refer to chapter 7, "Technical Specifications," to read about scanning performance.
7. Technical Specifications
The conditions for technical specifications are as follows, unless otherwise specified in each
section.
Conditions
Ambient temperature
and humidity:
Ambient light:
Light source:
Angles:
Curvature
Background:
Power supply voltage:
Decoding test:
Specification
CMOS area sensor
(black and white)
1280 (H) x 1024 (V)
30
527
630
Horizontal: 47
Vertical: 37.5
85
Room temperature (5 to 35º C)
Room humidity (45% to 85% RH)
1000 to 1500 lx (on the surface of a barcode)
3-wavelength inverter fluorescent light
α = 0°, β = +15°, γ = 0°
R = ∞
Barcode = black
Space = white
Margin = white
Background of label = black
3.6 V
Approve the performance when decoding is successful in 70% or more of
the tests
10
Opticon
OPI 4002
Specifications Manual
Unit
—
dots
fps
nm
nm
°
mm