Page 1
2D Barcode Scanner OPI 4002 The OPI 4002 is a 2D barcode scanner that •provides wireless communication compliant with IEEE Specifications Manual 802.15.4 between the OPI 4002 and a host system.
Opticon assumes no liability for any direct, indirect, consequential or incidental damages arising out of use or inability to use both the hardware and software, even if Opticon has been informed about the possibility of such damages.
• Wireless communication compliant with IEEE 802.15.4 (an interface standard for ZigBee physical layer and MAC layer) is the interface between the OPI 4002 and a host system • The scanner is supplied with an IEEE 802.15.4 dongle to establish wireless communication through the USB port of hosting hardware.
Opticon OPI 4002 Specifications Manual 4.3. Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a barcode surface is between zero and the following values: Incandescent light to 10,000 lx Fluorescent light to 10,000 lx Sunlight...
OPI 4002 Specifications Manual 5.3. AC Adaptor The OPI 4002 can be charged by an optional AC adapter of 6.0 V / 750 mA. This optional adapter is used for charging the internal battery. Conditions Connect 1Ω resistance to a power supply line in series and measure the current by the voltage between both ends of resistance.
Opticon OPI 4002 Specifications Manual 7.1. Test Samples: 1D Symbologies The size of barcodes does not include quiet zones. 1D Barcode Resolution Symbology Size (mm) Digits 0.254 mm Code 39 14 x 10 0.1 mm Code 39 11 x 10 0.26 mm...
Opticon OPI 4002 Specifications Manual 7.3. Print Contrast Signal (PCS) 0.45 or higher (over 70% of reflectivity of space and quiet zone). Reflectance of white bar-Reflectance of black bar PCS= Reflectance of white bar Scanning performance may decline if dirt or scratches mar the optical window. Keep the optical window clean.
Opticon OPI 4002 Specifications Manual 7.5. Scan Area and Resolution Depth of Field 7.5.1. The depth of field is measured from the edge of the optical window. Figure 1: Depth of field Symbology Resolution (mm) Decode Depth (mm) Code 39 55–75...
Opticon OPI 4002 Specifications Manual 7.6. Pitch, Skew, and Tilt Pitch: α = ±50° Skew: β = ±60° or less Tilt: γ = 360° or less Figure 2: Pitch, skew, and tilt Conditions Barcode Sample: CODE39 and PDF417 with 0.254 mm resolution, PCS: 0.9...
Opticon OPI 4002 Specifications Manual 7.7. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R≥20 mm. Figure 3: Curvature Conditions Barcode Sample: Symbology: 13-digit JAN, resolution: 0.26 mm, PCS: 0.9 mm...
Opticon OPI 4002 Specifications Manual 8. Aiming 8.1. Aiming Patterns During a scan, the green LED patterns shown below will be visible. These patterns assist you in aiming the scanner; they are superimposed on the illuminated scan field. The aiming patterns are only a guide. They do not indicate exact scannable width or distance between a scanner and a barcode.
Depends on the environment. Baud rate 250 Kbps Antenna 1/4λ surface-mounted type Communication configuration One OPI 4002 to one OPA 1001 Encryption 128-bit encryption 9.2. IEEE 802.15.4 Radio Equipment 9.2.1. The electromagnetic wave absorption (2.4 GHz) used by this product is also shared by various other devices.
The wireless communication channel settings can be adjusted. Data Memorizing Settings Outside the Communication Range: 10.2.3. DTME/DTMD Selecting “Data Memorizing Enabled” allows the scanner to read data outside the communication range and store the data in OPI 4002 memory. When the scanner...
Opticon OPI 4002 Specifications Manual returns to the communication range, it will be re-connected and the temporarily stored data will automatically be transmitted to the host. Note: When “Data Memorizing Disabled” is selected, the scanner will not read data outside the range.
Opticon OPI 4002 Specifications Manual 10.5. Default Settings 3: Other Communication Settings Item Setting Set IEEE address None Wireless channel CH15 Encryption Enabled Data memorizing Disabled 11. Serial Number and Labeling The serial number is written on the following label attached to the scanner.
Opticon OPI 4002 Specifications Manual 12. Packaging Specifications Put the scanner in a protective foam bag and place it in an individual packing box. Package dimensions (assembled): 255 mm (W) x 120 mm (D) x 105 mm (H) P R O TE C TI O N B A G E...
Opticon OPI 4002 Specifications Manual 12.1. Collective Packaging Specification B ox B 88010- 24 R ow s T he or der of ser i al - N o. C ar t on box:( N o. 18) B 88010- 25 ①...
13.4. Vibration Strength No malfunction occurred after the following vibration test. Put the OPI 4002 into a non-operating state and carried out sweeping for 30 minutes, increasing the frequency of the vibration from 10 Hz to 100 Hz with accelerated velocity of 2.0 G (19.6m/s...
Opticon OPI 4002 Specifications Manual 13.5. Dust and Drip Proof IEC IP42 Dust Prevention Level Details Prevention of objects larger than 1 mm. Most wires, screws, etc. Water Prevention Level Details Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle up to 15°...
Opticon OPI 4002 Specifications Manual 15. Regulatory Compliance 15.1. LED Safety All LED-based products are LED class 1 and are safe under reasonably foreseeable operating conditions. Do not stare into the beam. • JIS C6802: 2005: Class 1 • IEC 60825-1+A2: 2001 Class 1 15.2.
Peeling off the certificate label 15.7. State of California: Perchlorate Best Management Practices The batteries on some Opticon products may contain Perchlorate. To comply with California Perchlorate Best Practice Regulations and the Law for the Promotion of Utilization of Recyclable Resources (Japan), products that may contain Perchlorate materials should be properly labeled on the exterior of all outer shipping packages and/or in locations that otherwise satisfy the California Perchlorate Best Management Practices.
The scanner may be damaged by voltage drops. 16.5. AC/DC Adapter Opticon shall not be held responsible for any damages caused by using an AC adapter not provided by Opticon. Use only the supplied AC adapter with the enclosed region specific plugs for connection to the wall socket.