Optical Specifications; Laser Scan Specifications; Technical Specifications; Print Contrast Signal (Pcs) - Opticon OPL-9813 Specification Manual

Data collector with gps & bluetooth
Hide thumbs Also See for OPL-9813:
Table of Contents

Advertisement

7. Optical Specifications

7.1. Laser Scan Specifications

Parameter
Light-emitting element
Emission wavelength
Light output
Scanning method
Scanning speed
Scan angle
Resolution
Note: Refer to chapter 8, "Technical Specifications," to read about scanning
performance.

8. Technical Specifications

The conditions for technical specifications are as follows, unless otherwise specified in each
section.
Conditions
Ambient temperature
and humidity:
Ambient light:
Background:

8.1. Print Contrast Signal (PCS)

PCS=0.45 or higher (over 70% of reflectivity of space and quiet zone).
Scanning performance may decline if dirt or scratches mar the optical window. Keep
the optical window clean.

8.2. Minimum Resolution

0.127 mm
Specification
Red laser diode
650 ±10 (25° C)
1.0 or less
Bi-directional vibration mirror
100 ±20
Scan angle: 54 ±5
Read angle: 44 (Min)
0.127 and above
Room temperature (5 to 35º C)
Room humidity (45% to 85% RH)
500 to 900 lx
Barcode = black
Space = white
Margin = white
Background of label = black
10
Opticon
OPL-9813
Specifications Manual
Unit
nm
mW
scans/s
°
°
mm