4.3. Ambient Light Immunity

Decoding performance is guaranteed when the range of illumination on a barcode
surface is between zero and the following values:
Incandescent light
Fluorescent light
Sunlight
Direct light or specular reflection from a light source should be prevented from entering
the acceptance area.

5. Electrical Specifications

5.1. Main Battery

The main battery is a lithium-ion secondary battery.
Nominal capacity: 1100 mAh
Nominal voltage: 3.6 V
Item
Consumption
current

5.2. Battery Operating Time and Charging Time

Items
Battery life
Charging time
Note: Battery life may be shorter than specified above when the quality of the battery
pack is degraded.
Conditions
Ambient temperature: +25°
Symbology: 1-digit Code 39, PCS = 0.9, Resolution = 1.0 mm
Distance: 85 mm from the front edge of the scanner. (Single read)
to 10,000 lx
to 10,000 lx
to 100,000 lx
Specifications
15 mA (max.)
250 mA (max.)
550 mA (typ.)
Specifications
30 hours (min.)
3 hours
Conditions
When idle
When scanning
When charging
Conditions
1 scan / 5 s
Discharge and charge 300 times
Battery capacity 70% (1C charging)
Time necessary to fully charge an empty battery