3.6.2 Starting A New Field

When the iNEX is started it will load the last treatment used when the
system was shut down.
When starting a new field the current field should be cleared to ensure it
is ready for the new information.
1. From the Main Menu press FIELD.
2. Press RESTART.
3. If the current vehicle is configured
with only one section then the overall
width of the vehicle can be set on the
Restart Field screen by touching on
the Swath value.
4. Press TICK.
In the event there is previous treatment in
the memory slot it will be cleared from the screen and the new vehicle
swath width will be configured.
3.6.3 Recording Treatment
By default the iNEX will be setup to record treatment when the Master
Switch Status is pressed. There are a number of different options which
can be used to detect or trigger the master switch, see section 3.5.3
Master & Section Switch Detection.
If the system has not been configured for
a different master switch source simply
touching the Master Switch Status will
cause the green outlined triangle to
become solid green. This indicates the
master switch is ON, which more
importantly will cause the system to
record treatment on the Map screen.