NEC N8100-1220F User Manual page 329

Express5800/140re-4
Table of Contents

Advertisement

Error
Error message
code
8200
Online Spare Memory was not ready.
8201
Mirroring Memory was not ready.
8202
Memory RAID was not ready.
8300
Secondary BIOS is corrupted.
8400
Onboard PCIE#1 Link Failure
8401
Onboard PCIE#2 Link Failure
8412
PCI Slot#3 PCIE Link Failure
8413
PCI Slot#4 PCIE Link Failure
8414
PCI Slot#5 PCIE Link Failure
8420
Onboard PCIE#1 Link Width Error
8421
Onboard PCIE#2 Link Width Error
8432
PCI Slot#3 PCIE Link Width Error
8433
PCI Slot#4 PCIE Link Width Error
8434
PCI Slot#5 PCIE Link Width Error
Other POST Errors
The following message does not appear on the screen, however, it is recorded in the system event
log.
Error code
Description
8301
A BIOS Checksum error was detected in the
early stage of BIOS boot-up (Bootblock). The
control was transferred to the secondary BIOS.
(See Chapter 2 "Recovering BIOS Data".)
Troubleshooting 8-25
Recommended Action
DIMM type mismatch is detected when the
online spare memory feature is enabled.
Contact your service representative.
DIMM type mismatch is detected or
unnecessary installation in group #2 is detected
when the memory mirroring feature is enabled.
Check the DIMM type or installation. If the error
cannot be corrected, contact your service
representative.
Check if capacity, type, and installation status of
all DIMMs are correct.
Contact your service representative.
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service representative.
This is not a fatal error, but performance may be
reduced. Turn off the power once and then on
again to restart the server. If the error cannot be
corrected, contact your service representative.
Recommended Action
Contact your service
representative.