8-22 Troubleshooting
Error
Error message
code
0B5F
Forced to use Processor with error
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
0B66
DIMM group #7 has been disabled
0B67
DIMM group #8 has been disabled
0B70
The error occurred during temperature sensor
reading.
0B71
System Temperature out of the range.
The error occurred during voltage sensor
0B74
reading.
0B75
System voltage out of the range.
0B78
The error occurred during fan sensor reading
0B7C
The error occurred during redundant power
module confirmation
0B7D
The normal operation can't be guaranteed with
use of only one PSU
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted.
0B93
BMC SDR Repository empty.
Recommended Action
Because an error is detected in every
processor, the system is forcibly started.
Contact your service representative.
Contact your service representative.
Contact your service representative.
A fan failure or fan clogging may occur.
Contact your service representative to
request the maintenance.
Contact your service representative.
Contact you service representative to
replace the power supply unit.
Contact you service representative to add an
additional power supply unit or replace the
existing power supply unit.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service
representative.
All the commands and functions other than
the FRU command and the EMP function
can be used. This is not a fatal error. Turn
off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.