Additional Specifications; Input Conditions - Xantrex XFR 6-200 Operating Manual

Xfr 1200 watt series programmable dc power supply
Hide thumbs Also See for XFR 6-200:
Table of Contents

Advertisement

Features and Specifications
Specifications
Additional
Specifications
Rise Time (No Load, Full Load):
Fall Time (No Load):
Fall Time (Full Load):
Voltage Mode Transient Response:
Time Delay from power on until
output stable
1.
2.
Input
Conditions
Rated AC Input Voltage
Maximum AC Input Power
Operational AC Input Voltage
Maximum Input Current
Input Frequency Range
Power Factor
28
1
1
Measured with stepped 0-10 V analog programming source and a resistive load.
Time for the output voltage to recover within 0.5% of its rated value after a step change
in load current of 10% to 90% of rated output with an output setpoint between 50-100%
of rated value. Load slew rate <6 A/ms.
1
6 V to 60 V models: 100 ms;
100 V to 600 V models: 170 ms
6 V model: 1.5 s;
7.5 V to 60 V models: 3 s;
100 V to 600 V models: 4 s
6 V model: 10 ms;
7.5 V to 60 V models: 100 ms;
100 V to 600 V models: 170 ms
2
<3 ms
7 s maximum
100/120/200/220/230/240 Vac (nominal) ±10%
2600 VA
85-130 Vac or 190-264 Vac, 1
6 V model: 95-130 Vac or 190-264 Vac, 1
Auto range select function.
20 A maximum at 120 Vac,
12 A maximum at 230 Vac.
47-63 Hz
0.65 minimum at full load and 100 Vac input;
0.55 minimum at full load and 200 Vac input.
Operating Manual for XFR 1.2kW Series Power Supply
φ ;
φ .