Remote Operation
Remote Analog Programming of Output Voltage and Current Limit
Table 4.2 Power Supply Settings for Different Programming Sources
Output
Output Current Limit Programming Source
Voltage
0-5 Vdc
Programming
Source
0-5 Vdc
SW1:
set 3 and 4
open.
J2: jumper 1 to
3 and 2 to 3.
0-10 Vdc
SW1:
set 4 open.
J2: jumper 1 to
3 and 2 to 3.
0-5 k Resistor SW1:
set 1 closed,
3 and 4 open.
J2: jumper 1 to
3 and 2 to 3.
0-10 k
SW1:
Resistor
set 1 closed,
4 open.
J2: jumper 1 to
3 and 2 to 3.
None (Front
SW1:
Panel
set 4 open.
Control)
J2: jumper 2 to
3.
76
0-10 Vdc
0-5 k Resistor
SW1:
SW1:
set 3 open.
set 2 closed, 3
J2: jumper 1 to
and 4 open.
3 and 2 to 3.
J2: jumper 1 to
3 and 2 to 3.
SW1:
SW1:
default settings.
set 2 closed,
J2: jumper 1 to
4 open.
3 and 2 to 3.
J2: jumper 1 to
3 and 2 to 3.
SW1:
SW1:
set 1 closed,
set 1 and 2
3 open.
closed, 3 and 4
J2: jumper 1 to
open.
3 and 2 to 3.
J2: jumper 1 to
3 and 2 to 3.
SW1:
SW1:
set 1 closed.
set 1 and
J2: jumper 1 to
2 closed,
3 and 2 to 3.
4 open.
J2: jumper 1 to
3 and 2 to 3.
SW1:
SW1:
default settings.
set 2 closed,
J2: jumper 2 to
4 open.
3.
J2: jumper 2 to
3.
0-10 k Resistor None (Front
SW1:
set 2 closed, 3
open.
J2: jumper 1 to
3 and 2 to 3.
SW1:
set 2 closed.
J2: jumper 1 to
3 and 2 to 3.
SW1:
set 1 and 2
closed,
3 open.
J2: jumper 1 to
3 and 2 to 3.
SW1:
set 1 and
2 closed.
J2: jumper 1 to
3 and 2 to 3.
SW1:
set 2 closed.
J2: jumper 2 to
3.
Operating Manual for XFR 1.2kW Series Power Supply
Panel Control)
SW1:
set 3 open.
J2: jumper 1 to
3.
SW1:
default settings.
J2: jumper 1 to
3.
SW1:
set 3 open,
1 closed.
J2: jumper 1 to
3.
SW1:
set 1 closed.
J2: jumper 1 to
3.
SW1:
default settings.
J2: no jumper