Introduction; Calibration Setup; Section 5. Introduction; Service Environment And Precautions - Xantrex XFR 6-200 Operating Manual

Xfr 1200 watt series programmable dc power supply
Hide thumbs Also See for XFR 6-200:
Table of Contents

Advertisement

Section 5. Calibration

Introduction

Adjustments to programming and readback accuracy for the power supply are made
using cover-off procedures which must be performed by a service technician.

Calibration Setup

Service
Environment
and
Precautions
Equipment
You will need the following equipment when calibrating your power supply.
Required
Release 3.1
WARNING
HIGH ENERGY AND HIGH VOLTAGE WARNING
Exercise caution when using and calibrating a power supply. High energy levels
can be stored at the output voltage terminals on a power supply in normal
operation. In addition, potentially lethal voltages exist in the power circuit and on
the output and sense connectors of a power supply with a rated output greater
than 40 V. Filter capacitors store potentially dangerous energy for some time
after power is removed.
Follow established antistatic procedures.
Work at a bench with adequate room and support for the test unit and for all

equipment required.

To reduce shock hazard, use only an insulated, straight-bladed screwdriver when
calibrating trim potentiometers.
NEVER calibrate these units alone. Ensure that someone is present who can help
should an accident occur.
5 1/2-digit true RMS voltmeters (DVMs) (±0.05% accuracy) with test leads
Current shunt 1 mV/AMP (±0.25%) and connecting wire. The recommended
current ratings for the DC shunt and connecting wire must be at least 10%
greater than the power supply's output current rating. See also Table 2.4,
"Current Carrying Capacity for Load Wiring".
Non-conducting, straight-bladed screwdriver