Installation
Functional Tests
Current Mode
1. Ensure that the front panel power switch is set to OFF.
Operation
2. Turn the voltage and current controls on the front panel fully counter-clockwise.
Check
3. Connect the DC shunt across the output terminals on the rear panel.
4. Connect the DVM across the DC shunt.
5. Turn the AC power switch to ON.
6. Turn the voltage control one (1) or two (2) turns clockwise.
7. Turn the current control slowly clockwise.
8. Compare the DVM reading with the front panel ammeter reading using I=V/R
9. Turn the front panel power switch to OFF.
10. Disconnect the DVM and the shunt.
Front Panel
1. Turn the front panel power switch to ON.
Function
2. Set voltage and current controls fully clockwise. Push the STANDBY switch to
Checks
3. Press the STANDBY switch to its IN position.
4. Press the OVP CHECK switch and check that the voltmeter displays
5. Turn the OVP SET potentiometer counter-clockwise and check that the
6. Press the STANDBY switch to its OUT position.
7. Press the V/I CHECK switch and check that the voltmeter and ammeter display
8. Turn the front panel power switch to OFF.
Note
interface has been installed in your power supply.
44
where I is the current, V is the DVM reading, and R is the DC shunt resistance.
The minimum control range is from zero to the maximum rated output for the
power supply model. The current mode LED turns on.
its IN position and check that the voltmeter reading falls to zero and the red S/D
(Shutdown) LED turns on. Push the STANDBY switch once again to reset it to
its OUT position. The S/D LED turns off and the voltmeter reading returns to its
previous value.
approximately the model-rated output voltage plus 10%.
voltmeter reading decreases. Continued turning (up to 20 turns) will see the
reading decrease to approximately 5% of the model-rated voltage output. Turn
the OVP SET potentiometer clockwise until the voltmeter once again displays
approximately the model-rated output voltage plus 10%.
approximately the power supply output ratings.
You can use the front panel LOCAL button only when a digital programming