Local And Remote Sensing; Sense Wiring; Local Sensing; Figure 2.11 J10 Sense Connector - Xantrex XFR 6-200 Operating Manual

Xfr 1200 watt series programmable dc power supply
Hide thumbs Also See for XFR 6-200:
Table of Contents

Advertisement

Local and Remote Sensing

Use connections at the rear panel J10 sense connector to configure the power supply
for local or remote sensing of output voltage. See Figure 2.11 for a drawing of the
sense connector.

Sense Wiring

For lowest noise performance, use shielded pair wiring of 16 to 24 AWG for remote
sense lines. Strip wires 0.26 in. (6.5 mm), insert and tighten the wire clamp.
Local
We ship the power supply with the rear panel J10 sense connector jumpered for local
Sensing
sensing of the output voltage. See Table 2.5 for the list of connector functions and a
description of local sense connections. With local sensing, the output voltage is
regulated at the output terminals (or bus bars). This method does not compensate for
voltage losses in the load lines, so it is recommended only for low current
applications or applications for which load regulation is not essential.
Note
minimize the effects of line impedance on the regulation of the supply.

Figure 2.11 J10 Sense Connector

Release 3.1
WARNING
There is a potential shock hazard at the sense connector when using a power
supply with a rated output greater than 40 V. Select wiring with a minimum
insulation rating equivalent to the maximum output voltage of the power supply
for use as local sense jumpers or for remote sense wires. For example, select
TEW-105, 105 °C, 600 V wiring for use with a 600 V, 2 A model power supply.
Ensure that connections at the load end are shielded to prevent contact with
hazardous voltages.
When using local sense connections, use the largest practical load wire size to
(Shown with local sense jumpers connected.)
Installation
Local and Remote Sensing
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xfr 1200 watt seriesXfr 7.5-140Xfr 12-100Xfr 20-60Xfr 35-35Xfr 40-30 ... Show all

Table of Contents