Start Recording
Record the video from the selected camera.
1. Beside the Start Recording check box, click
Detail.
2. In the Alarm Recording Setting dialog box,
select the camera to enable/disable video
recording. Enable All to select all cameras.
3. In the Frame Rate selection, select As
Setting to record the number of frames
based on the Recording Setting.
4. In the Start Record prior text box, mark
and set the number in second for the
program to begin recording after the alarm has been trigger. The time range is 1~10
seconds.
5. In the Stop Record after text box, mark and set the number in second for the program to
continue recording after the alarm has ended. The time range is 1~999 seconds. If user
doesn't mark and set the time, the alarm recording will continue recording until alarm is
reset.
6. Click OK to accept the new settings and Cancel to exit without saving.
- PTZ preset point
Position the PTZ camera based on the preset point
setting. Beside the PTZ preset point check box, click
Detail. In the Trigger PTZ Preset Setting dialog box,
select the PTZ camera number then select the Enable
check box. Select the position of the PTZ camera when
the alarm is activated and ended. For the PTZ camera
end point, user can also select on preset position or Auto
Pan between preset position groups.
- Send to CMS (Central Management System)
Enable/disable the selected camera to
send video to CMS when the alarm is
activated. Beside the Send to CMS check
box, click Detail. In the CMS Setting,
select the camera to enable/disable
sending the video to CMS. Enable All to
select all cameras. Then, click OK to
accept the new settings and Cancel to exit
without saving.