ACCESS USING TACACS+
8.3
Configuring TACACS+ with EnerVista Secure Web Management Software
8–6
To access the TACACS servers, select the Administration > User
Mgmt > TACACS+ menu item.
By default, no TACACS servers are defined.
To add a server, click on the Add button as shown below.
Note that the TCP port field can be left blank – port 49 is used as a default port. Up to five
TACACS+ servers can be defined.
After the configuration is completed,
Save the settings.
Enable the TACACS+ services by using the Status drop down menu.
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
CHAPTER 8: ACCESS USING TACACS+