GE MULTILINK ML2400 Instruction Manual page 133

Ethernet communications switch
Hide thumbs Also See for MULTILINK ML2400:
Table of Contents

Advertisement

CHAPTER 8: ACCESS USING TACACS+
MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
Example 8-1: Configuring TACACS+:
ML2400#
show tacplus servers
ID
TACACS+ Server
Port
=======================================
1
10.21.1.170
2
--
3
--
4
--
5
--
ML2400#
user
ML2400(user)##
show tacplus status
TACACS+ Status: Disabled
ML2400(user)##
tacplus enable
TACACS+ Tunneling is enabled.
ML2400(user)##
tacserver add id=2 ip=10.21.1.123 encrypt=enable ke
TACACS+ server is added.
ML2400(user)##
show tacplus servers
ID
TACACS+ Server
Port
=======================================
1
10.21.1.170
2
10.21.1.123
3
--
4
--
5
--
ML2400(user)##
tacserver delete id=2
TACACS+ server is deleted.
ML2400(user)##
show tacplus servers
ID
TACACS+ Server
Port
=======================================
1
10.21.1.170
2
--
3
--
4
--
5
--
ML2400(user)##
tacplus disable
TACACS+ is disabled.
ML2400(user)##
Encrypt
Key
49
Enabled
secret
--
--
--
--
--
--
--
--
--
--
--
--
Encrypt
Key
49
Enabled
secret
49
Enabled
some
--
--
--
--
--
--
--
--
--
Encrypt
Key
49
Enabled
secret
--
--
--
--
--
--
--
--
--
--
--
--
ACCESS USING TACACS+
8–5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MULTILINK ML2400 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF