CHAPTER 17: MISCELLANEOUS COMMANDS

17.1.3 Configuring Alarm Relays with EnerVista Secure Web Management Software

MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
Alarm relays (continued)
ML2400(alarm)##
show alarm
Alarm Events Configuration
--------------------------
Alarm Status: DISABLED
Relay Closure Time Period: 5 Seconds
EventId
Description
------------------------------------------
1
S-RING OPEN
2
Cold Start
3
Warm Start
4
Link Up
5
Link Down
6
Authentication Failure
7
RMON Raising Alarm
8
RMON Falling Alarm
9
Intruder Alarm
10
Link Loss Learn Triggered
11
Broadcast Storm Detected
12
STP/RSTP Reconfigured
ML2400(alarm)##
exit
ML2400#
To customize the alarm relays,
Select the Configuration > Alarms menu item.
Each alarm can be enabled or disabled form the screen shown above. All alarms can be
enabled or disabled using the Alarm Status drop down menu. Relay closure times can be
set using the drop down menu.
After changing the Alarm settings, save the configuration using the
save icon (
MISCELLANEOUS COMMANDS
Mode
NOT ENABLED
MOMENTARY
NOT ENABLED
MOMENTARY
NOT ENABLED
MOMENTARY
NOT ENABLED
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
),
17–5