ACCESS USING RADIUS
7–12
The Max Request column represents the maximum times the authenticator retransmits an
EAP request packet to the supplicant before it times out. Values are integers ranging from
1 to 10, with a default of 2.
The port authentication characteristics define how the authenticator (ML2400 switch) does
the re-authentication with the supplicant or PC. These are defined through the
Configuration > Radius > Port > Access > Reauth menu item.
The Reauth Period represents the time the authenticator waits before a re-authentication
process will be done again to the supplicant. Values range from 10 to 86400 seconds, with
a default of 3600 (1 hour).
The Configuration > Radius > Port > Stats menu item illustrates the radius statistics for
each port.
After all the port characteristics are enabled,
Do not forget to save the configuration using the save (
and enabling RADIUS from the Configuration > Radius > Server
menu.