IOP Shutdown Operation
This command removes the specified IOP from the Endurance configuration, shuts down the
IOP, and automatically reboots it. When it reboots, the IOP rejoins the Endurance server
configuration. If you do not want the IOP to rejoin, power it off or use the IOP Disable
command.
Command
IOPn Shutdown Operation From IOPx
Console Syntax MTCCONS IOPn Shutdown Operation From IOPx
-disable_safeguard
Note: The
n – the ID number of the IOP (1 or 2) to shut down
Variables
x – the ID number of the IOP (1 or 2) that issues the shutdown command
Check the Windows Event Viewer for a message that indicates that the CE
Results
has been shut down, disabled, or removed from service.
See Also
IOP Disable Operation
IOP Enable Operation
IOPn.Monitor Show Configuration
Commands
-disable_safeguard
online or for the CE boot disk if the CE is running.
argument is needed only for the last IOP
5-23