To shut down an IOP:
Step
Action
1
Follow the instructions in the procedure
Shutting Down the Endurance Server
on
page
2
Use Endurance Manager to ensure the
following:
• That the IOP you want to shut down
is not marked as the source of a
mirror copy.
• That the other IOP is active.
• That the other IOP has public
network connectivity (IOPx.Ethernet
cable is online).
3
From Endurance Manager, issue the
command IOPx Disable Operation.
4
From the local IOP:
• Make sure that the keyboard and
mouse are controlling the IOP's
operating system.
• Shut down Windows.
5
When prompted, power off the IOP.
9-6
9-9.
Notes
Do this only if you are willing to remove the
Endurance server from service. If you do not
want to remove the Endurance server from
service, continue with the next step.
If possible, perform any necessary backups for
non-mirrored devices on the IOP that you want
to shut down.
Immediately after removing IOPx, verify the
public network connectivity on the remaining
IOP.
If necessary, enter the hotkey sequence to
switch control to the IOP's operating system.
Be sure not to have Windows restart after you
shut it down.
Do this only when prompted.
HP Netserver AA Solution Administrator's Guide