State Description - HP NetServer AA 6200 Administrator's Manual

Hp netserver aa solution administrator's guide v4.0 sp1
Hide thumbs Also See for NetServer AA 6200:
Table of Contents

Advertisement

State
Description
Faulted
Indicates a disk failed a read or write request after repeated retries. The disk is not
available for use by the CE operating system.
You can use Endurance Manager to re-enable a disk that has experienced unrecovered
failures and return it to service. You do not need to reboot the IOP to bring the disk back
online. An ensuing mirror copy to the disk may correct bad spots present on the failed
disk. However, if the disk has completely or substantially failed, it will continue to revert to
the faulted state. In this case, you should replace the disk.
A disk is also regarded as faulted if it failed during previous operation of its IOP. For
example, if a disk experienced read or write errors and was deemed to be faulted, then
the faulted state would remain across IOP reboots, even if you replaced the failed disk.
In this case, you must explicitly enable the disk to clear its faulted condition.
Disabled
An administrator may disable a mirrored disk at any time. The mirrored disk remains
disabled until it is explicitly enabled. It is possible to delay or halt a mirror copy by
disabling the target of the copy.
Warning: Do not disable the source of a mirror copy or all usable (online) disks in a
Mirrored Disks in the Endurance Server
Because disk remirroring ensures availability of data on the server, the disks in the Endurance
server have these characteristics:
The target disk of a mirror copy cannot fully service CE requests until its mirror copy
completes.
If the source disk of that mirror set becomes unavailable for any reason before the mirror
copy completes, the CEs no longer have access to that mirror set.
If the CEs cannot access the CEs' boot disks, the CEs reset.
If a mirrored disk fails, use Endurance Manager to attempt to enable that disk. If enabling the
disk succeeds, a mirror copy is automatically queued.
Endurance Overview
Table 2-8 Mirrored Disk States (Continued)
mirror set, because this would make the entire mirror set inaccessible.
If all members of a mirror set are inaccessible during CE boot time, the
Windows operating system does not recognize the mirror set even if the disks
are later returned to an online state. In this case, a full reboot of the CE is
required to enable Windows to recognize the mirror set.
2-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Netserver aa solution

Table of Contents