A# Command 7; A# Command 9; Panel Wide Relays; Printer 17 Fail - Bosch D9112B Program Entry Manual

Control panel
Table of Contents

Advertisement

D9112B | Program Entry Guide |

A# Command 7

Default:
Blank
Selection:
Blank, 1 to 128, A, B, or C
Activates when Command 7 is executed at a
command center assigned to the specified area.
Time
must be programmed in Bell Parameters. The
relay provides steady output and remains active until
the bell time expires, a valid passcode is entered, or
the panel is reset.

A# Command 9

Default:
Blank
Selection:
Blank, 1 to 128, A, B, or C
Activates when Command 9 is executed at a
command center assigned to the specified area.
Time
must be programmed in Bell Parameters. The
relay provides steady output and remains active until
the bell time expires, a valid passcode is entered, or
the panel is reset.
9.2

Panel Wide Relays

One relay number can be assigned for each of the
events listed in this section. All areas share the same
relay for these events. Do not use the same relay
number for two different functions.

Printer 17 Fail

Default:
Blank
Selection:
Blank, 1 to 128, A, B, or C
Activates when Printer 17 (SDI address 17 fails). It
remains active until the printer responds. The printer
Printer Supervision
must be supervised;
Wide Parameter must be programmed YES.

Printer 18 Fail

Default:
Blank
Selection:
Blank, 1 to 128, A, B, or C
Activates when Printer 18 (SDI address 18) fails. It
remains active until the printer responds. The printer
Printer Supervision
must be supervised;
Wide Parameter must be programmed YES.

Printer 19 Fail

Default:
Blank
Selection:
Blank, 1 to 128, A, B, or C
Bosch Security Systems | 2/04 | 74-06145-000-D
Activates when Printer 19 (SDI address 19) fails. It
remains active until the printer responds. The printer
must be supervised.
Wide Parameter

AC Failure

Burg
Default:
Selection:
Activates when the panel responds to an AC power
failure as programmed in
Power Supervision section. It remains active until AC
power is restored.
has no effect on this relay.

Battery Trouble

Default:
Burg
Selection:
Activates when battery voltage falls below 12.1 V or
is missing.
effect on this relay.

Phone Fail

Default:
Selection:
Activates when a telephone line failure alarm is
generated. (See
programming section.) This relay provides steady
output until a phone line
acknowledged by the receiver.

Comm Fail

Default:
in Panel
Selection:
Activates when the panel is unable to communicate
a report. See
explanation of Comm Fail. This relay provides
steady output until a report is successfully sent.
Note:
Points can be programmed to be silent alarms that
become audible after two attempts at communicating a
in Panel
report (see Point Index Audible After 2
Failures). If you use silent points and never want
them to become audible, do not use this relay in
conjunction with an audible device.
Printer Supervision
must be programmed YES.
Blank
Blank, 1 to 128, A, B, or C
AC Fail Time
Buzz on AC/Low Battery Fail
Blank
Blank, 1 to 128, A, B, or C
Buzz on AC/Low Battery Fail
Blank
Blank, 1 to 128, A, B, or C
Alarm On Fail
in the Phone
Restoral
report is sent and
Blank
Blank, 1 to 128, A, B, or C
Panel Wide Parameters
EN | 85
Panel
in
in the
has no
Phone for an