2.5

Command Center

This programming module contains three
programming categories:

Cmd Cntr Assignment

Area Text
Custom Function
2.5.1
Cmd Cntr Assignment
Determines if the command center is supervised and
which area information the command center
displays.

Cmd Center #

Default:
1
Selection:
1 to 8
Enter the command center address you want to
program. Corresponding DIP switches on the
command center are set to identify each command
center. See the D9112B Program Record Sheet for DIP
switch settings for each address.

CC# Supervised

This entry tells the panel if the command center at
the address specified is supervised. The panel polls
the command centers by address number. If a
supervised address does not respond, an
report with the address number is sent to the log.
SERVC KEYPAD displays at all other command
centers, and a report is sent to the
route, if programmed.
Default:
No
Selection:
Yes or No
Only one command center can be installed
Yes
with this address number (see the command
center manual for address switch settings).
If the address number is supervised and the
DIP switches for more than one command
center are programmed for this address, the
command centers intermittently sound the
keypad encoding tone.
More than one command center can be
No
installed with this address number.
Command centers with the same address
echo the operation of all other command
centers with the same address (in other
words, they all show the same displays and
emit the same tones at the same time).
Bosch Security Systems | 2/04 | 74-06145-000-D
Area Wide Parameters
SDI Fail
Diagnostic
phone
System Security Notice: Install unsupervised
command centers inside the protected area. All
equipment installed outside of the protected area
should be enclosed in tamper resistant housing.

CC# Scope

Scope determines if the command center is capable
of viewing the status and arming and disarming
areas other than the one to which the command
center is assigned.
A Security System Owner's Guide is
provided with each panel. This guide further
explains how Scope and other relationships
like Authority Levels and Skeds affect
command center displays and operation.
Press the [SPACE] bar to scroll through the
selections. Press [ENT] when the correct selection
appears in the display.
Default:
PanelWide (address 1 only)
Selection:
PanelWide, Account. Area, or No
Keypad 0 or 1
PanelWide
A Panel-Wide Command Center can
view information and perform arming
and disarming functions for all areas
in the panel. A Panel-Wide command
center can cross account boundaries.
Account
An Account Command Center can
view information, and perform arming
and disarming functions for all areas
that are assigned to the same account
as the area where the command
center is assigned. An Account
command center cannot cross
boundaries.
Area
An Area Command Center can view
information and perform arming and
disarming functions only for the area
to which it is assigned.
No Keypad
No command center installed at this
address. CALL FOR SERVICE
displays at command centers
programmed for this address.