Netcom Functionality; Standard Features; Points; Areas And Accounts - Bosch D9412G Operations & Installation Manual

Table of Contents

Advertisement

D9412G/D7412G | Operation & Installation Guide |
2.3.4

NetCom Functionality

The D6600 NetCom System supports data network
communications. NetCom allows the D6600 receiver to
connect to various network topologies, specifically
Ethernet and Token Ring. NetCom also lets this receiver
process messages to and from most networks using
TCP/IP protocols. Connection to a data network can be
implemented using the COM4 and/or a COM1
connection from the D6600 receiver to the D6680
Network Adapter. Reports from alarm control panels via
phone lines or Ethernet and Token Ring data networks
can be sent to the D6600 receiver and on to the central
station automation software and/or the network printer
via LAN or WAN. Alarm control panels can be
monitored on the network for their status.
2.4

Standard Features

2.4. 1

Points

The Bosch Security Systems D9412G Control Panel
provides a maximum of 246 points of protection. The
D7412G Control Panel provides up to 75 points of
protection. Point programming parameters determine the
panel's response to open and shorted conditions on the
point's sensor loop. Points are programmed individually
with several options to custom-fit the protection to the
installation.
Points 1 to 8 are located on the circuit board (on-board
points). They are standard sensor loops. The remaining
off-board points are POPIT points using D8128D
OctoPOPITs, D8125 POPEX Modules and D9127/
D8127 POPITs.
2.4.2

Areas and Accounts

The system supports a maximum of eight separate areas.
All points can be assigned to a single area or spread out
over up to eight areas.
The panel is armed/disarmed by area, and several areas
can be armed and disarmed with one menu function. A
passcode can also be assigned an authority level that
allows a user to arm an area from a remote command
center in another area. Assigning each area its own
account number creates eight separate accounts in one
panel. Assigning the same account number to different
areas groups them together in a single account.
Area options include exit tone and delay, separate fire
and burglary outputs, and multiple opening and closing
windows. Area type can be used to create area
interdependencies.
Bosch Security Systems | 10/03 | 43488E
2.0 Overview
2.4.3

Communicator

The control panel uses a built-in digital communicator
to send reports to the receiver. The panel transmits
reports in either the Modem IIIa
D6500 receiver's MPU and line cards must have
software revision 8.00 (or greater) installed to accept
Modem IIIa
2
reports from the panel. Cycle the
receivers down to print the software revision numbers.
The panel connects to an RJ31X or RJ38X jack for
phone line seizure. Connection to the RJ31X complies
with FCC regulations for using the public telephone
network. The panel can be programmed to direct reports
to four separate phone numbers. Adding the D928 Dual
Phone Line Switcher Module allows the connection and
supervision of a second phone line.
The system has routing capabilities allowing groups of
Event Reports to be directed to four different
destinations. Each report group can be programmed to
report to one or more destinations. Primary and backup
reporting paths can be programmed for each destination
and each report group. A custom option allows
specification of individual Event Reports to be sent.
2.4.4

Command Centers

A maximum of 32 unsupervised command centers can
be connected to the system. The available power,
number of supervised command centers, and number of
areas used affect the total number of command centers
that can be connected.
The system can supervise up to eight command centers.
The panel transmits a Serial Device Trouble Report SDI
Failure in the Modem IIIa
the BFSK format if it loses communication with a
supervised command center. More command centers can
be added, but only eight can be supervised. Table 7
shows the command centers compatible with the
D9412G/D7412G Control Panels. See Command Center
in the D9412G/D7412G Program Entry Guide for
complete details on programming command center
options.

Table 7: Compatible Command Centers

Model
Display
D1255
16-character
alphanumeric
D1256
16-character
alphanumeric
D1257
16-character
alphanumeric
D1260
4-line by 20-character
alphanumeric
D720
8 LED
EN | 14
2
or BFSK format. The
2
format or Trouble ZN D in
Application
Fire/Burglary/Access
Fire
Fire
Fire/Burglary
Fire/Burglary

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412g

Table of Contents