Cc# Area; Area Text; Area; Area # Is On - Bosch D9112B Program Entry Manual

Control panel
Table of Contents

Advertisement

D9112B | Program Entry Guide | 2.0

CC# Area

Default:
1
Selection:
1 to 8
Each installed command center must be assigned to
an area of the D9112. This allows proper event
displays as well as user authority operations.
Blank entries are not acceptable.
2.5.2

Area Text

Create custom "Idle Text" displays for the command
centers.

Area

Default:
1
Selection:
1 to 8
Each area number you are programming.

Area # Is On

Program Record Sheet
Default:
See
16 alphanumeric characters - enter
Selection:
alphabetic characters A to Z in capital
letters.
Note:
Period (.), comma (,), percent (%), parenthesis [()],
equal (=), greater/less than (< >), exclamation (!),
and colon (:) are not allowed.
Text that displays at command centers assigned to
this area when the area is master armed. The text for
each area is programmed separately, so each area
can have a custom display.
Check the Program Record Sheet (P/N: 74-06447-000)
for default text.

Area # Not Ready

Program Record Sheet
Default:
See
16 alphanumeric characters - enter
Selection:
alphabetic characters A to Z in capital
letters.
Note:
Period (.), comma (,), percent (%), parenthesis [()],
equal (=), greater/less than (< >), exclamation (!),
and colon (:) are not allowed.
Text that displays at command centers assigned to
this area when the area is disarmed and has faulted
points. Enter the text that displays at command
centers when the area has faulted controlled points.
Bosch Security Systems | 2/04 | 74-06145-000-D
Area Wide Parameters
The text for each area is programmed separately, so
each area can have a custom display.
Check the Program Record Training Sheet (P/N: 74-
06447-000) for default text.

Area # Is Off

Default:
Selection:
Note:
Text that displays at command centers assigned to
this area when the area is disarmed. Enter the text
that displays at command centers when the area is
ready to be armed (there are no faulted controlled
points).
The text for each area is programmed separately, so
each area can have a custom display.
Check the Program Record Sheet (P/N: 74-06447-000)
for default text.

Area # Acct Is On

Default:
Selection:
Note:
When all areas in the account are master armed, the
Area # Is On
The
that are assigned to this area. (See Cmd Cntr
Assignment
Number
Each area can have unique
can program the same text in each area of the
account.
A blank entry disables the
this area. Each area's armed text continues to display
after the last area in the account is armed.
See
Program Record Sheet
16 alphanumeric characters - enter
alphabetic characters A to Z in capital
letters.
Period (.), comma (,), percent (%), parenthesis [()],
equal (=), greater/less than (<>), exclamation (!),
and colon (:) are not allowed.
Blank
16 alphanumeric characters - enter
alphabetic characters A to Z in capital
letters.
Period (.), comma (,), percent (%), parenthesis [()],
equal (=), greater/less than (< >), exclamation (!),
and colon (:) are not allowed.
text is replaced by
Acct Is On
text appears at all command centers
CC# Area
, and Area Parameters
.)
Acct Is On
Acct Is On
EN | 43
Acct Is On
text.
Account
text, or you
display for

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents