Programming Two Opening Windows On The Same Day; Programming To Link Two Days Over Midnight; W## Close Early Begin; Table 17: Programming For Two Opening Windows On The Same Day - Bosch D9112B Program Entry Manual

Control panel
Table of Contents

Advertisement

D9112B | Program Entry Guide | 2.0
2.4.1

Programming Two Opening Windows on the Same Day

Table 17: Programming for Two Opening Windows on the Same Day

W#
Day of Week
1
S M T W T F S
2
S M T W T F S
0101
Do not program a single window to cross the midnight boundary. This window stop time must be later
0101
than the window start time. To program a window that effectively crosses the midnight boundary, you
0101
have to program two windows.
For example, to program two windows for an area that opens between 11:30 p.m. and 12:30 a.m., five
days a week, use two windows as shown in Table 18:
2.4.2

Programming to Link Two Days Over Midnight

Table 18: Programming to Link Two Days Over Midnight

W#
Day of Week
1
S M T W T F S
2
S M T W T F S

W## Close Early Begin

Default:
_ _ : _ _
HH:MM (hours and minutes)
Selection:
00:00 to 23:59
This program item is one of three required to create
a closing window. To finish programming a closing
window,
Close Window Start
Stop
must be programmed.
Close Early Begin
Use
panel to look for a closing window. When
and
Closing
reports are enabled, arming the area
between midnight and the
Closing
generates a
report. In addition:
If Disable O/C in Window is YES:
-
Arming the area between the
Begin
time and the
time generates a
Closing Early
Early Begin
Window Start
modifier is not sent.)
Bosch Security Systems | 2/04 | 74-06145-000-D
Area Wide Parameters
OPEN
Early
Start
Stop
Begin
06:00
07:00
08:00
13:00
14:00
15:00
OPEN
Early
Start
Stop
Begin
22:00
23:30
23:59
00:00
00:00
00:30
and
Close Window
to set the time you want the
Opening
Close Early Begin
Close Early
Close Window Start
Closing
report and adds a
Close
modifier. (If the
Close
time is the same as the
time, the CLOSING EARLY
CLOSE
Early
Start
Stop
Begin
CLOSE
Early
Start
Stop
Begin
Arming the area between the
-
Window Start
Stop
log but does not send the
the central station.
-
Arming the area after the
Stop
Begin
sooner) generates a
adds a
Disable O/C in Window
If
the area generates a
"early" or "late" modifier, regardless of when the
area is armed.
time
When you are programming multiple windows to
activate on a single day, program the windows in
chronological order. Be careful not to program a
Close Early Begin
window's
between any other window's
Close Window Stop
and
eXcept On
Holiday
Area(s)
Holiday
Index
Yes No
1 2 3 4
1 2 3 4 5 6 7 8
1 2 3 4
Yes No
1 2 3 4 5 6 7 8
eXcept On
Holiday
Area(s)
Holiday
Index
Yes No
1 2 3 4
1 2 3 4 5 6 7 8
Yes No
1 2 3 4
1 2 3 4 5 6 7 8
Close
Close Window
and the
time creates a local event in the D9112
Closing
Close Window
Close Early
and the next window's
time (or midnight, whichever comes
Closing
reports and
Closing Late
modifier.
is NO, disarming
Closing
report without the
time for a time that is
Close Window Start
time.