Ph# Test/Stat Rpt; Ph# Diagnostic; Ph# Relay; Ph# Skeds - Bosch D9112B Program Entry Manual

Control panel
Table of Contents

Advertisement

D9112B | Program Entry Guide | 1.0

Ph# Test/Stat Rpt

Default:
Blank
Selection:
Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.
Test
Status
reports and
Skeds section of the program. For
Sked Function Code #9. For
Sked Function Code #10.
Test
Status
and
reports are identified at the D6500
using the account number for Area 1.
Expand Test Rpt
If
includes additional system events, if the panel is
currently in one of these conditions: Prog Access
OK, SDI Failure, Comm Failure, Battery
Missing, Battery Low, Pt Bus Trouble,
AC Failure, Params Bad Cksm, Log
Threshold, Log Overflow, Bad Call to
RAM, and User Tamper.
After a Reset-Bye or disable restart, the panel
checks to see if the following conditions exist. If they
do, the panel sends appropriate reports with the test
Log Threshold
report:
to RAM
User Tamper
, and
are cleared and do not report at test time.
To clear Bad Call to RAM and User Tamper
events, simply contact the panel with RAM II. To
clear Log Threshold and Log Overflow
contact the panel with RAM II and perform a
Receive Log and Set Pointer function from the
Logger menu.

Ph# Diagnostic

Default:
Blank
Selection:
Blank, P, B, or D
See the introduction to Phone Routing for a
description of the selections.
If a Parameter Checksum Fail (
report is received, the user can silence the panel's
buzzer, but cannot clear the system trouble display.
To correct a Parameter Checksum Fail condition, re-
load the program into the panel using RAM or the
D5200
Bosch Security Systems | 2/04 | 74-06145-000-D
Panel Wide Parameter
reports are enabled in the
Test
reports, see
Status
reports, see
Test
in Phone is YES, the
Log Overflow
Bad Call
,
,
. All other system events
Parm Cksum Fail

Ph# Relay

Default:
Selection:
See the introduction to Phone Routing for a
description of the selections.

Ph# Skeds

Default:
Selection:
See the introduction to Phone Routing for a
description of the selections.
report
Note:
The panel uses Skeds 18 to 49 for opening and closing
windows and Skeds 50 to 64 for User Access
Windows. Routing Skeds activity to a receiver when
using these features can result in excessive receiver
traffic.

Ph# RAM

Default:
Selection:
See the introduction to Phone Routing for a
description of the selections.
These events are associated with RAM functions.
RAM reports are identified at the D6500 using the
account number for Area 1.
RAM Access Fail may indicate a wrong
passcode when communicating with the panel, or a
valid RAM session was terminated by a means other
than a Good-bye or Reset-bye command. Log
Threshold is programmed in RAM Parameters
% Full
. Remote Reset indicates a Reset-Bye
command issued from RAM. Bad Call to RAM
indicates that the panel called RAM but was unable
to connect.

Ph# Power/Phone

)
Default:
Selection:
See the introduction to Phone Routing for a
description of the selections.
Blank
Blank, P, B, or D
Blank
Blank, P, B, or D
Blank
Blank, P, B, or D
Blank
Blank, P, B, or D
EN | 18
Log

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents